Project Description

The temperature of the sucked liquid should not exceed 80°C without cooling fan and 150°C with cooling fan.

ErP : These fans are within the scope of Directive 2009/125 / EC. This law does not apply in the following cases:

- Working in potentially explosive atmospheres (ATEX)
- Operation at high temperatures (fans designed with cooling fan)
- Operation at temperatures below -40°C

- Working in toxic, corrosive or corrosive environments (use of materials such as AISI 304, AISI 316, manganese steels).
These series are centrifugal backward curved fans and therefore Ntarget = 61 is expected (Reg. UE N.327 / 2011).
Efficiency IE2 motors conforming to IEC 60034-30 are taken into account in ErP calculations.
special rate> In the case of 1.11, please note that Directive 2009/125 / CE applies, but these fans are not subject to the energy efficiency restrictions imposed and thus the verification of these parameters.

HAVA AKIMI

V = 1.200÷33.600 M3/SAAT

BASINÇ

PT = 260÷2.800 KG/M2

Product Technical Information

AIR FLOW 45 – 112 m3/minute
INPUT PRESSURE 290 – 358 kg/m2
OUTPUT PRESSURE 305 – 370 kg/m2
ENGINE BOARD 132 M – 4-pole
INSTALLED POWER 7.5 kW
ROTATION SPEED 1450 rpm
SPEED LIMIT 1500rpm
LIQUID TYPE Clean
INLET FLANGE ⌀361mm
OUTLET FLANGE 315x224mm
WEIGHT WITHOUT MOTOR 233 Kg
SE 2 15 Kgm2

Use : For suction of clean and dusty air. Such high-pressure fans are characterized by a high output, which saves electrical energy, as they have a special fan impeller mounted with reverse blades (negative).
This type of fans is particularly suitable for pneumatic conveying of small capacities in cement plants, in the air supply of cupolas in foundries and oil burners, in mills, in “pasta” factories, in the chemical, metallurgical and iron industries. medium and high pressures are required.

– Easy setup

– High energy saving

– Silent

– Made with high quality raw materials

– Long years of use guarantee