EUK 1401/A

EUK 1401/A


Project Description

The temperature of the sucked liquid should not exceed 80°C without cooling fan and 150°C with cooling fan. For higher temperatures it is necessary to make some changes in the structure of the fan.

ErP : These fans are within the scope of Directive 2009/125 / EC. This law does not apply in the following cases:

- Working in potentially explosive atmospheres (ATEX)
- Operation at high temperatures (fans designed with cooling fan)
- Operation at temperatures below -40°C

- Working in toxic, corrosive or corrosive environments (use of materials such as AISI 304, AISI 316, manganese steels).
These series are centrifugal backward curved fans and therefore Ntarget = 61 is expected (Reg. UE N.327 / 2011).
Efficiency IE2 motors conforming to IEC 60034-30 are taken into account in ErP calculations.

HAVA AKIMI

V = 800÷150.000 M3/SAAT

BASINÇ

PT = 70÷1095 KG/M2

Product Technical Information

AIR FLOW 670 – 2300 m3/minute
INPUT PRESSURE 406 – 755 kg/m2
OUTPUT PRESSURE 512 – 822 kg/m2
ENGINE BOARD 315 L – 4-pole
INSTALLED POWER 250 kW
ROTATION SPEED 1470 rpm
SPEED LIMIT 1490 rpm
LIQUID TYPE Clean, Dusty, Material transfer.
INLET FLANGE ⌀1128mm
OUTLET FLANGE 1120x800mm
WEIGHT WITHOUT MOTOR 1120 Kg
SE 2 300 Kgm2

Use : For absorbing very dusty air containing various types of material in suspension. The main feature of such fans is that high efficiency (resulting from the use of an inverted blade rotor, special profile) is associated with the suction of powdery liquids or those containing granular materials. Also these fans are characterized by a very flat curve of the absorbed power so that the motor is not overloaded when running with open inlets.
They are installed in joinery to transport saw dust and wood shavigs, excluding filamentous material, in mechanical industries to absorb metal chips, pneumatic conveying of cement plants, ceramic plants, mills, feed mills, tanneries, foundries, textile and chemical. It is used in industries where it is necessary to transport harmful air at low and medium pressure, and in all these applications in general.

– Easy setup

– High energy saving

– Silent

– Made with high quality raw materials

– Long years of use guarantee

– High efficiency